One platform, three layers of control

Each module is complete on its own and can be contracted separately. Together, they give you a single view of your entire facility — from utility spend to the critical equipment that can't fail.

01
Module

Invoice Management

The invoice stops being a document you file away and becomes a strategic input. It runs at scale: thousands of invoices a month, hundreds of providers, one single environment — no rigid templates.

  • Zero manual entryAutomatic forwarding from the utility provider straight into the platform.
  • Multi-serviceElectricity, water, and sewer in the same environment.
  • Keycloak securityRole-based access, on-demand OTP, access traceability.

Capture without rigid templates

Processes invoices from utility providers and third-party billing statements or HOA charges — structured and unstructured data alike.

EPM · Celsia · Emcali · Enel · Codensa · Vatia

Direct ERP integration

Delivers the exact flat file your finance team needs each billing cycle, with zero manual re-keying.

Line-item detail

Deep historical analysis per site: cost, tariff, and consumption broken down to isolate specific overcharges.

Geographic heat map

Spatial visualization that instantly flags which sites are paying above-average rates or consumption.

Backed claims

Detects overcharges against the site's history and backs — with data — the claims process with the utility provider.

ESG traceability

Automatic calculation of tons of CO₂ and environmental equivalencies as a direct input to your sustainability report.

02
Module

Smart Metering

The invoice only tells you how much you paid. UAI breaks down real consumption —electrical and process— point by point and in real time, correlates occupancy and weather, and acts on the operation via BMS.

  • Beyond the buildingAlso covers industrial process variables.
  • Fast deploymentGateway with autonomous 4G/5G, no need to touch your IT network.
  • ScalableAdd measurement points without rebuilding the architecture.

Disaggregated, real-time consumption

By zone, by equipment, by system — not a single monthly figure on the invoice.

Correlated data sources

Cross-references outside weather, real occupancy (access control), and room bookings to decide with context.

Real BMS control

Turns HVAC on, off, and adjusts it automatically — not just alerts, it acts.

Typical 20–35% reduction in unoccupied zones

Centralized CCTV and access

Camera views and access-point status in the same operational dashboard for the building.

Industrial process variables

Steam pressure, compressed air, tank levels, chiller temperature and flow, pumps, and generators.

4–20mA sensors · RS485 · Modbus RTU

Solar generation

Net balance of photovoltaic generation when the site has panels installed.

03
Module · Live MVP

Infrastructure Management

Continuous monitoring and predictive maintenance for the assets that keep you running: UPS units, precision cooling, generators — any brand, without touching your equipment.

  • Read-onlyNon-intrusive telemetry, zero writes to your equipment.
  • Predictive + prescriptiveUAI Expert doesn't just project the failure — it tells you what to do.
  • Standards-backedASHRAE, IEEE 1100, IEEE 485, TIA-942, NFPA 110, IEC 62040-3.

Executive dashboard

Monitored equipment, operational health, active alarms, and global MTBF, live and by client or site.

Individual diagnostics

Equipment telemetry by hour, day, and month: load, runtime, temperature, voltage, pressure, current — depending on asset type.

Failure projection

Failure risk assessed across 4 horizons — today, 30, 90, and 180 days — to plan budget and interventions ahead of time.

Prescriptive UAI Expert

Every finding comes with severity, technical detail, a concrete recommendation, and the international standard behind it.

N+1 redundancy awareness

Recognizes standby or alternating equipment so it doesn't raise false alarms over normal operation.

Monthly management report

KPIs, events, per-equipment diagnostics, and prioritized recommendations — a document ready for your board, with no manual work.

The engine behind all three modules

It doesn't just monitor. It interprets.

UAI Expert is an AI trained by our top electrical and mechanical engineers. It cross-references the asset's spec sheet, maintenance history, and live telemetry — and delivers a prescriptive diagnosis: what's happening, why, and what to do.

  • Embedded expert knowledgeYour specialists' judgment, available 24/7 and at scale.
  • Multi-resolution telemetryEquipment variables by hour, day, and month, with historical series.
  • Standards-backedEvery finding cites the standard: ASHRAE, IEEE, TIA-942.
Symmetra UPS · Output loadLive
HourlyDailyMonthly
19.0%
Avg. load
21.9%
Peak
64d
MTBF
Deployment and security

Connected in days, not months

No need to touch your internal IT network. UAI connects to your equipment with its own gateway and transmits autonomously.

1

Connect your equipment

Sensors and meters are installed on your existing equipment —electrical, thermal, or process— without changing its configuration.

2

The gateway transmits

Concentrates telemetry over Modbus/RS485 and sends it to the cloud over autonomous 4G/5G — independent of your site's data network.

3

UAI Expert interprets

The AI processes the telemetry and delivers alerts, trends, and actionable diagnostics right in your dashboard.

Non-intervention principle: read-only on your equipment

UAI's acquisition agent operates with minimal privileges: in the vast majority of cases, it only reads telemetry — it never writes to or modifies an asset's configuration. The only control actions (like turning an HVAC unit on or off) are enabled explicitly and narrowly during implementation, with full traceability of every change.

  • Multi-tenant architecture with total isolation between organizations
  • Outbound HTTPS over TLS 1.2+ — no inbound ports opened from the internet
  • Read-only credentials per device (SNMP community string or Modbus user)
  • Centralized authentication with Keycloak: on-demand OTP, roles, and access traceability
Supported protocols
SNMP v1 · v2c · v3Modbus TCP/IPBACnet/IPREST API / HTTP
Compatible with equipment from

APC · Eaton · Vertiv · Liebert · MGE Galaxy · Schneider Electric · Socomec · ABB · Riello · Ioxus · Powest · Stulz · Emerson · Airedale · Johnson Controls · Carrier · Daikin · Trane — among others, regardless of manufacturer.

Integrates without replacing

If you already monitor with Schneider Electric DataCenter Expert, PME, Eaton IPM, ABB Ability, Vertiv Trellis, Nlyte, or an existing BMS, UAI layers on top as the intelligence over that data.

Take the first step

Pick the module that matters most right now

Each module is contracted separately. Start where it hurts most — we'll show you the rest when you're ready.